75.5268.01 20070111 Page 1 of 7
FALCON DR / FALCON XL-DR
USER’S GUIDE
MOTION SENSORS FOR INDUSTRIAL DOORS
FALCON DR: double relay / high mount FALCON XL-DR: double relay / low mount
Technology : Microwave and
microprocessor
Transmitter frequency : 24.125 GHz
Transmitter radiated power : <20 dBm EIRP
Transmitter power density : < 5 mW/cm²
Mounting height
FALCON DR : from 11.5’ (3.5m) to 23’ (7m)
FALCON XL-DR : from 6.5’ (2m) to 11.5’ (3.5m)
Tilt angles : 0° to 180° in elevation
Detection zone
FALCON DR
(mounting height of 5m)
:
13’ (W) x 16’ (D)
4m (W) x 5m (D)
FALCON XL-DR
(mounting height of 2.5m)
:
13’ (W) x 6.5’ (D)
4m (W) x 2m (D)
Detection mode : Motion
Minimum speed : 2 in (5cm)/s (measured in the
sensor axis)
Supply voltage : 12V to 24V AC ±10%
12V to 24V DC +30% / -10%
Mains frequency : 50 to 60 Hz
Power consumption : < 2W (VA)
Two Output relay (free of potential change-over contact)
Max. contact voltage : 42V AC
Max. contact current : 1A (resistive)
Max. switching power : 30W (DC) / 60VA (AC)
Hold time : 0.5s to 9s (adjustable)
Temperature range : -22°F to +122°F (-30°C to +60°C)
Degree of protection : IP65
Norm conformity : R&TTE 1999/5/EC
EMC 89/336/EEC
Dimensions : 4” (W) x 5” (D) x 3 ¾” (H)
102 mm (W) x 127 mm (D) x 96 mm (H)
Weight : 0.88 lbs (0.4 kg)
Material of housing : ABS and polycarbonate
Material of bracket : Anodized aluminium
Length of cable : 33’ (10m)
Manual adjustment
Orientation of sensing field (mechanically)
Multiple functions (by push buttons)
Remote control adjustments
Sensitivity
Hold time
Detection mode
Pedestrian and parallel traffic rejection mode
Output configuration
Security
The sensor must be firmly
fastened to prevent from
vibrating.
The sensor must not be placed
directly behind a panel or any kind
of material.
The sensor must not have
any object likely to move or
vibrate in its sensing field.
The sensor must not have any
fluorescent lighting in its
sensing field.
DESCRIPTION OF
THE SENSOR
INSTALLATION
TIPS
TECHNICAL
SPECIFICATION
Tranceiver module
(planar antenna)
Green LED
Infrared Receiver
Red LED
2 Push Buttons
Microprocessor
Terminal block
Page view 0
1 2 3 4 5 6 7

Summary of Contents

Page 1 - FALCON DR / FALCON XL-DR

75.5268.01 20070111 Page 1 of 7 FALCON DR / FALCON XL-DR USER’S GUIDE MOTION SENSORS FOR INDUSTRIAL DOORS FALCON DR: double relay / high mount

Page 2

75.5268.01 20070111 Page 2 of 7 • Loosen the retaining nut until the cable slides easily into the grommet ; • Partially unscrew the 2 front cove

Page 3 - H = 11.5 ft

75.5268.01 20070111 Page 3 of 7 FALCON (Mounting height: 16.5’ (5m) FALCON (Mounting height: 11.5’ (3.5 m) FALCON XL (Mounting height: 8’

Page 4

75.5268.01 20070111 Page 4 of 7 1. DESCRIPTION OF THE INFRARED REMOTE CONTROL • Open the battery compartment at the back of the remote control

Page 5 -

75.5268.01 20070111 Page 5 of 7 Note: All parameters or functions listed in the following tables are only accessible if the sensor is in adj

Page 6

75.5268.01 20070111 Page 6 of 7 OUTPUT REDIRECTION Key 2: towards or away mode detection Motion towards the detector triggers relay 1. Motion aw

Page 7

75.5268.01 20070111 Page 7 of 7 SYMPTOM PROBABLE CAUSE CORRECTIVE ACTION The door will not open and no red LED lights up. The sensor power is o