BEA Stanley Dip Switch I User Manual

Browse online or download User Manual for Garage Door Opener BEA Stanley Dip Switch I. USERS GUIDE LO-21U LOCKOUT RELAY [en] [it]

  • Download
  • Add to my manuals
  • Print
  • Page
    / 5
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
75.1041.06 20060605 Page 1 of 5
PRODUCT
DESCRIPTION
TECHNICAL
SPECIFICATIONS
USERS GUIDE
LO-21U
LOCKOUT RELAY
SAFETY
PRECAUTIONS
The LO-21U (PN: 10LO21U) is a micro-processed lock out module designed to operate on swing door applications with
BEA’s Bodyguard or DK-12 overhead presence sensor. The LO-21U interprets door open or door closed position based
upon motor voltage input. The motor voltage information is sent from the LO-21U to the Bodyguard or DK-12 via data lines.
The LO-21U provides optional safety beam input (dry contacts) to override the inhibit signal during closing.
ANSI / BHMA 156.10-2005 requires the use of a sensor or photobeam on the swing side of the door when using
a header mounted safety sensor, such as the Bodyguard or DK12. For more information reference the ANSI
156.10 standard.
DESCRIPTION SPECIFICATION
Supply voltage 12 to 24 VAC / 15 to 24 VDC
Operating frequency 4 MHz (Microprocessor)
Power consumption 10 mA at rest, 50 mA Maximum
Output (2) SPST Relays
Maximum voltage – Relay contacts 60 VDC, 120 VAC
Maximum current – Relay contacts 2A DC, 0.5 A AC
Shut off all power going to the header before attempting any wiring procedures.
Maintain a clean & safe environment when working in public areas.
Constantly be aware of pedestrian traffic around the door area.
Always stop pedestrian traffic through the doorway when performing tests that may result in unexpected
reactions by the door.
Always check placement of all wiring before powering up to insure that moving door parts will not catch any
wires and cause damage to equipment.
Ensure compliance with all applicable safety standards (i.e. ANSI A156.10) upon completion of installation.
COMPONENT ID
Green LED Dipswitches
Red LED
!
CAUTION
Page view 0
1 2 3 4 5

Summary of Contents

Page 1 - LOCKOUT RELAY

75.1041.06 20060605 Page 1 of 5 PRODUCT DESCRIPTION TECHNICAL SPECIFICATIONS USERS GUIDE LO-21U LOCKOUT RELAY SAFET

Page 2 - DOOR CONTROL

75.1041.06 20060605 Page 2 of 5 WIRING INSTRUCTIONS DIPSWITCH SETTINGS 1. Wire the LO-21U according to the chart b

Page 3 -

75.1041.06 20060605 Page 3 of 5 DIPSWITCH SETTINGS – Cont. 2. Use the chart (at right) for a quick-reference for

Page 4

75.1041.06 20060605 Page 4 of 5 SET-UP INSTRUCTIONS The following instructions pertain to the setup procedures an

Page 5

75.1041.06 20060605 Page 5 of 5 COMPANY CONTACT TROUBLE-SHOOTING SET-UP INSTRUCTIONS – Cont. 8. When all functio

Comments to this Manuals